prometheus/node_exporter · error
Could not derive a monitoring name for
Error message
Could not derive a monitoring name for
What it means
hwmonName could not build a readable chip name for the hwmon device at the given sysfs directory: neither the device's name file nor the device name yielded a usable metric name, and even the fallback hwmonX directory name cleaned to an empty string. This happens for hwmon entries with missing or empty name attributes under /sys/class/hwmon.
Solutions
- Check the directory: `cat /sys/class/hwmon/hwmonX/name` and `readlink /sys/class/hwmon/hwmonX/device`; a missing/empty name indicates a driver or hardware issue.
- Update the kernel/driver so the hwmon device exposes a proper name attribute.
- Disable the hwmon collector (--collector.hwmon) if the broken device cannot be fixed and its metrics are not needed.
Defensive patterns
Strategy: fallback
When it happens
Trigger: Thrown at collector/hwmon_linux.go:414 when the library encounters an invalid state.
Common situations: See trigger scenarios.
AI-assisted analysis of prometheus/node_exporter@17ddd77c59 (2026-09-07).
Data as JSON: /api/errors/93d7dbd83d646645.
Report an issue: GitHub.
Appendix: source
Thrown at collector/hwmon_linux.go:414
return cleanName, nil
}
}
// it looks bad, name and device don't provide enough information
// return a hwmon[0-9]* name
realDir, err := filepath.EvalSymlinks(dir)
if err != nil {
return "", err
}
// take the last path element, this will be hwmonX
_, name := filepath.Split(realDir)
cleanName := cleanMetricName(name)
if cleanName != "" {
return cleanName, nil
}
return "", errors.New("Could not derive a monitoring name for " + dir)
}
// hwmonHumanReadableChipName is similar to the methods in hwmonName, but with
// different precedences -- we can allow duplicates here.
func (c *hwMonCollector) hwmonHumanReadableChipName(dir string) (string, error) {
sysnameRaw, nameErr := os.ReadFile(filepath.Join(dir, "name"))
if nameErr != nil {
return "", nameErr
}
if string(sysnameRaw) != "" {
cleanName := cleanMetricName(string(sysnameRaw))
if cleanName != "" {
return cleanName, nil
}
}
return "", errors.New("Could not derive a human-readable chip type for " + dir)View on GitHub (pinned to 17ddd77c59)