risingwavelabs/risingwave · error · SinkError::Config
Turbopuffer namespace must be 1 to 128 bytes
Error message
Turbopuffer namespace must be 1 to 128 bytes
What it means
Turbopuffer namespace names must be between 1 and 128 bytes. validate_namespace enforces this before the sink builds the request URL or validates the connector config (try_from). A non-conforming namespace value in the WITH clause, or in the namespace_column data of a row, raises this error.
Solutions
- Set turbopuffer.namespace to a 1–128 byte string in the WITH clause.
- Clean the namespace_column data so values are non-empty and ≤128 bytes.
- If namespaces come from a column, filter out rows with empty/too-long values before sinking.
Example fix
// before WITH (connector='turbopuffer', turbopuffer.namespace='', ...) // after WITH (connector='turbopuffer', turbopuffer.namespace='my-index-v1', ...)
Defensive patterns
Strategy: validation
Validate before calling
fn namespace_len_ok(ns: &str) -> bool {
!ns.is_empty() && ns.len() <= 128
} Prevention
- Validate namespace values (length 1–128) before CREATE SINK.
- Filter empty namespace_column values upstream.
- Avoid unbounded auto-generated namespace names.
When it happens
Trigger: Setting turbopuffer.namespace to an empty string or a string longer than 128 bytes in the sink WITH options; or a row whose namespace_column value is empty or exceeds 128 bytes, evaluated by url_for_row at write time.
Common situations: Copy-pasting a namespace with trailing whitespace stripped to empty; generating namespaces from data where some values are empty strings; very long auto-generated namespace names.
Understand the failure class
Background: "value must be between 0 and 1" / "out of range" / "must not be negative" errors: fixing range-validation failures across open-source libraries — this error's family across 42 libraries.
Related errors
- Turbopuffer namespace must match [A-Za-z0-9-_.]
- column not found in the downstream SQL Server table
- `commit_checkpoint_interval` must be greater than 0
- `commit_checkpoint_interval` must be greater than 0
- config error
AI-assisted analysis of risingwavelabs/risingwave@6469eb736d (2026-09-11).
Data as JSON: /api/errors/10cb6efb70f177aa.
Report an issue: GitHub.
Appendix: source
Thrown at src/connector/src/sink/turbopuffer.rs:726
CompactedOp::Delete => deletes.push(id),
}
}
(upsert_rows, deletes)
}
fn document_id_from_i64(value: i64) -> DocumentId {
if value < 0 {
tracing::warn!(
value,
"cast negative turbopuffer integer document id to unsigned integer"
);
}
DocumentId::U64(value as u64)
}
fn validate_namespace(namespace: &str) -> Result<()> {
if namespace.is_empty() || namespace.len() > 128 {
return Err(SinkError::Config(anyhow!(
"Turbopuffer namespace must be 1 to 128 bytes"
)));
}
if !namespace
.bytes()
.all(|b| b.is_ascii_alphanumeric() || matches!(b, b'-' | b'_' | b'.'))
{
return Err(SinkError::Config(anyhow!(
"Turbopuffer namespace must match [A-Za-z0-9-_.]{{1,128}}"
)));
}
Ok(())
}
fn parse_column_selection(
value: Option<&str>,
schema: &Schema,