vitessio/vitess · warning
GetSchema(cluster = %s, keyspace = %s, tablet = %s) failed t
Error message
GetSchema(cluster = %s, keyspace = %s, tablet = %s) failed to acquire schemaReadPool: %w
What it means
For each tablet selected during GetSchema, vtadmin acquires schemaReadPool before issuing Vtctld.GetSchema; an Acquire failure (ctx cancelled/deadline while waiting for a slot) is wrapped with cluster, keyspace, and tablet alias and recorded into the error recorder. It is a resource-limiting failure, not a schema error.
Source
Thrown at go/vt/vtadmin/cluster/cluster.go:1694
for _, tablet := range tablets {
wg.Add(1)
go func(tablet *vtadminpb.Tablet, sizesOnly bool) {
defer wg.Done()
span, ctx := trace.NewSpan(ctx, "Vtctld.GetSchema")
defer span.Finish()
req := opts.BaseRequest.CloneVT()
req.TableSizesOnly = sizesOnly
req.TabletAlias = tablet.Tablet.Alias
AnnotateSpan(c, span)
annotateGetSchemaRequest(req, span)
span.Annotate("keyspace", keyspace)
span.Annotate("shard", tablet.Tablet.Shard)
if err := c.schemaReadPool.Acquire(ctx); err != nil {
err = fmt.Errorf("GetSchema(cluster = %s, keyspace = %s, tablet = %s) failed to acquire schemaReadPool: %w", c.ID, keyspace, tablet.Tablet.Alias, err)
rec.RecordError(err)
return
}
resp, err := c.Vtctld.GetSchema(ctx, req)
c.schemaReadPool.Release()
if err != nil {
err = fmt.Errorf("GetSchema(cluster = %s, keyspace = %s, tablet = %s) failed: %w", c.ID, keyspace, tablet.Tablet.Alias, err)
rec.RecordError(err)
return
}
if resp == nil || resp.Schema == nil {
return
}
View on GitHub (pinned to 01a25a7d17)
Solutions
- Increase schemaReadPool size in vtadmin config
- Check the wrapped cause: DeadlineExceeded indicates sustained pool saturation
- Reduce the tablet set queried (use narrower opts/tablet filters)
- Investigate slow tablets (overloaded mysqld, network) that hold pool slots
Defensive patterns
Strategy: retry
Validate before calling
// Go: check remaining context budget before the fan-out
deadline, ok := ctx.Deadline()
if !ok || time.Until(deadline) < poolWaitBudget {
return fmt.Errorf("insufficient deadline for schema fan-out")
} Try / catch
schema, err := c.GetSchema(ctx, req)
if err != nil {
if strings.Contains(err.Error(), "failed to acquire schemaReadPool") {
// pool exhaustion: retry with backoff or raise pool size
}
return err
} Prevention
- Size schemaReadPool to the expected tablet fan-out width
- Replace or quarantine persistently slow tablets
- Limit per-request tablet counts
- Monitor schemaReadPool saturation metrics
When it happens
Trigger: Large GetSchema fan-outs across many tablets holding all schemaReadPool slots, with the caller's ctx cancelled or deadline exceeded while a goroutine waits to query a specific tablet.
Common situations: Schema refresh across hundreds of tablets with a small pool; slow/unresponsive tablets making GetSchema calls hold slots for a long time; UI request timeouts cancelling ctx mid-wait.
Related errors
- GetWorkflows(keyspace = %s, active_only = %v) failed to acqu
- GetBackups(%s/%s) failed to acquire backupReadPool: %w
- GetCellInfo(%s) failed to acquire topoReadPool: %w
- GetKeyspace(%s) failed to acquire topoReadPool: %w
- GetKeyspaces() failed to acquire topoReadPool: %w
AI-assisted analysis of vitessio/vitess@01a25a7d17 (2026-09-01).
Data as JSON: /api/errors/467b99121370dda7.